AGC Pyrobel® Vision Line

Seamless butt-glazed fire-resistive safety glass solutions: achieve virtually uninterrupted transparency with UL-Certified 60-120 Minute Temperature-Rise Wall Systems, fabricated in North America

Rigorously Tested for Maximum Fire-Resistive Transparency

As a premier fabricator and national supplier, McGrory Glass provides the technical expertise and manufacturing scale necessary to secure complex architectural projects. Our specialized fabrication of the AGC Pyrobel® Vision line represents a commitment to delivering high-performance, fire-resistive solutions that act as a total thermal shield. By utilizing advanced butt-glazed technology with a narrow 4mm silicone joint, we empower architects to meet stringent ASTM E119 and UL 263 thermal barrier requirements while achieving expansive, nearly seamless glass walls.

Pyrobel® Vision Line successfully passes rigorous hose-stream testing, proving its structural integrity under extreme conditions. This innovative system eliminates the need for vertical mullions, offering a clear, uninterrupted field of vision that matches the aesthetics of modern float glass. Its low-iron, high-transparency composition ensures exceptional optical clarity and color neutrality, creating daylight-filled environments that remain cool and safe for evacuation.

Available through our in-house fabrication, the AGC Pyrobel® Vision line satisfies both ANSI Z97.1 and CPSC 16 CFR 1201 impact safety standards, making it ideal for high-visibility partitions in high-traffic areas. Whether you are designing a contemporary healthcare facility or a sustainable corporate campus, McGrory Glass delivers the precision-engineered, butt-glazed solutions required for modern, eco-conscious developments. We combine the reliability of a national leader with the customized service of a dedicated fabrication partner, ensuring your next project achieves maximum protection with a sleek, minimalist design.

Note: AGC Pyrobel® is a fire-resistive glazing solution fabricated by McGrory Glass. Unlike fire-protective glass, Pyrobel® acts as a total thermal barrier, meeting the stringent Temperature-Rise requirements of ASTM E119 and UL 263 for applications where radiant heat must be blocked to allow for safe evacuation.

Icon Target Environment Icon Key Threat Mitigation Icon Visual Goal

Expansive Office Partitions

Barrier to Radiant Heat (ASTM E119): Blocks thermal transfer to keep egress corridors safe for 45-120 minutes.

Seamless Transparency: Narrow 4mm vertical joints eliminate bulky mullions for an uninterrupted, “all-glass” look.

High-Traffic Medical Corridors

Impact & Sound Safety: Meets CPSC Cat II impact standards while providing superior acoustic insulation for patient privacy.

Daylight Integration: Maximizes natural light flow through large, butt-glazed spans to support healing and wellness.

University Lobby Hubs

Multi-Hazard Protection: Extensively tested for heat-barrier performance, impact resistance, and hose-stream endurance to withstand extreme thermal shock.

Minimalist Aesthetics: Low-iron glass composition ensures clear, color-neutral views that match non-rated surrounding glazing.

Secure Government Facilities

Thermal Separation: Prevents fire and heat spread between secure zones without compromising visibility.

Unobstructed Sightlines: High optical quality allows for 360-degree situational awareness and clear monitoring.

Attributes
  • Fire
  • Impact-Safety
  • Hose-Stream
  • Ultra-Narrow Joint (4 mm)
  • Security Options
  • UL Listed
  • Intertek Listed
  • LEED

AGC Pyrobel® Vision Line Resources

View by Category
  • BIM files
  • Brochures
  • Datasheets
View all Resources

Technical Data

Product Name Minute Rating Applications Performance Standards Heat Barrier Performance Hose-Stream Test Impact-Safety-Rated Appearance

AGC Pyrobel® Vision Line 60 Minute

60 Minute

Interior/Exterior

ASTM E119, NFPA 80, UL 263, ULC S101, ANSI Z97.1, CPSC 16CFR1201

Yes

Pass

Yes

Clear, Low-Iron Glazing

AGC Pyrobel® Vision Line 120 Minute

120 Minute

Interior/Exterior

ASTM E119, NFPA 80, UL 263, ULC S101, ANSI Z97.1, CPSC 16CFR1201

Yes

Pass

Yes

Clear, Low-Iron Glazing

Listings & Test References

ASTM
  • ASTM E119
NFPA
  • NFPA 80
UL
  • UL 263
ULC
  • ULC S101
ANSI
  • ANSI Z97.1
CPSC
  • 16 CFR 1201
Product Certification Testing References
  • ASTM E119: Standard Test Methods for Fire Tests of Building Construction and Materials
  • NFPA 80: Requires that fire doors be inspected and tested immediately after the initial installation and then at a minimum annually after that.
  • NFPA 263: Standard Method of Test for Heat and Visible Smoke Release Rates for Materials and Products
  • ANSI Z97.1 and CPSC 16 CFR 1201 Cat I and Cat II (Category I and/or Category II) Safety- Impact performance criteria